AquaCooly IK-V / IK-H

- Cooling water recooler

AquaCooly IK-V / IK-H

Cooling systems from 2.3 kW to 500 kW for indoor and outdoor installation

Systems of this size incorporate decades of experience in refrigeration engineering and modern production methods and set standards in economics and reliability. Fine tuning of cooling power and pump performance ensures a high degree of trouble-free operation.

Standard equipment includes an insulated water container, a built-in agitator to enhance heat extraction from the liquid, adjustable electronic controls with digital display and a malfunction alarm with fault indication. There is a neutral contact for a connection to external controls. The equipment can be supplied in numerous variations. Our flexibility in manufacture enables us to satisfy almost all customer requirements.

IK-V 3-5

AquaCooly model IK-V 3-5

System featuring semi-hermetic motorised compressor

These are top of the range liquid recoolers manufactured by ETSCHEID. In principle the design corresponds with units with fully-hermetic motorised compressors. With semi- hermetic equipment it is possible to use the refrigeration system at ambient temperatures higher than 42°C. The compressors are particularly tough and are suitable for operation under extreme conditions.

Operation

The standard unit AquaCooly cools down the liquid to the desired temperature between 10°C and 25°C. In the insulated liquid storage tank a built-in agitator ensures a good mixing of the liquid and an intensive heat exchange. When the desired temperature is reached, the thermostat switches off. When the temperature of the fluid rises, the thermostat automatically switches on the cooling again. Thus, the temperature of the liquid remains constant.To control the temperature of the liquid you can read the value on the display.

Schema IK-V

Schematic diagram IK-V

Components

  1. Fully hermetically sealed motor compressor
  2. Air-cooled condenser with axial fan
  3. Liquids collector
  4. Drier
  5. Solenoid valve
  6. Sightglass with moisture indicator
  7. Thermostatic expansion valve
  8. Venturi distributor
  9. Float valve
  10. Centrifugal pump
  11. Stirrer
  12. Evaporator basket
  13. Insulated water basin
  14. Electronic thermostat
  15. High pressure/low pressure pressostat
IK-V 2

AquaCooly model IK-V 2

Design variants of AquaCooly IK-V and IK-H

Besides the standard units IK-V and IK-H with air cooled condenser, following variations are also available:

  • units with a water cooled condenser for connection to a circulation water system
  • units with a flow evaporator
  • units with a radial fan for connection to an available ventilation system
  • units with noise reduction for use in laboratories for example

Over and above that our units can be supplied with accessories, e.g. with special pumps, special paint colour, in stainless steel, liquid circuit for corrosive agents, units with special voltage, units with a heating and much more....

Technical specifications

Technical specifications for standard units, model IK-V (fully-hermetic)

air cooled fully-hermetic AquaCooly IK-V with pipe-coil evaporator
IK-V 1.4 IK-V 2 IK-V 3 IK-V 5 IK-V 7 IK-V 9 IK-V 13 IK-V 18
Refrigerant R 134 a R 134 a R 134 a R 134 a R 134 a R 449 A R 449 A R 449 A
Nominal power kcal/h* 1500 2000 3200 5200 7800 9750 13000 18000
Nominal power kW* 1,8 2,3 3,7 6,1 8,1 11,3 15,1 20,9
Noise level 3 m distance dB(A) 57 67 67 67 69 69 72 72
Noise level 10 m distance dB(A) 55 59 59 59 61 61 67 67
Pump type NPY-2051 CM 1-4 CM 1-4 CM 1-4 CM 1-6 CM 1-6 CM 3-6 CM 3-6
Basin capacity litre 40 87 87 87 140 140 300 300
Pipe connexion DN 10 R 3/4" R 3/4" R 3/4" R 3/4" R 3/4" R 1" R 1"
Air flow rate ml/h 1000 1000 2600 2750 4000 4000 8000 8700
Compressor load kW** 0,7 0,96 1,71 2,13 2,6 3,6 5,1 7,0
Pump output kW** 0,25 0,46 0,46 0,46 0,46 0,46 0,65 0,65
Power load kW 1,1 1,73 2,53 2,93 3,7 4,8 7,3 9,3
Voltage V/Hz 1x230/
N/PE/50
1x230/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
Maximum current A 8,2 10,8 5,5 6,5 9,5 10,7 15,8 20,6
Dimension: l mm 1000 730 730 730 860 860 1470 1470
Dimension: w mm 440 675 675 675 760 760 830 830
Dimension: h mm 500 1165 1165 1165 1370 1370 1560 1560
Weight kg 85 148 152 165 205 220 420 465
Refrigerant weight kg 0,5 2,5 2,5 3,0 4,0 7,0 8,0 13,5
* The mentioned cooling capacity refers to an ambient temperature of 32°C and a water inlet temperature of 15°C. At lower water inlet temperature the cooling capacity reduces approx. 3% per °C.
** Nominal capacity according to the manufacturer.


air cooled fully-hermetic AquaCooly IK-V with pipe-coil evaporator
IK-V 23 IK-V 28 IK-V 34 IK-V 40 IK-V 50 IK-V 60 IK-V 70
Refrigerant R 449 A R 449 A R 449 A R 449 A R 449 A R 449 A R 449 A
Nominal power kcal/h* 23800 28000 34000 40000 50000 60000 70000
Nominal power kW* 27,7 32,5 39,5 46,5 58,2 70,0 81,5
Noise level 3 m distance dB(A) 72 72 72 79 79 79 79
Noise level 10 m distance dB(A) 67 67 67 77 77 77 77
Pump type CM 3-6 CM 10-3 CM 10-3 CM 10-3 CM 10-3 CM 15-2 CM 15-2
Basin capacity litre 500 500 500 500 500 500 500
Pipe connexion R 1" R 1 1/4" R 1 1/4" R 1 1/2" R 1 1/2" R 1 1/2" R 1 1/2"
Air flow rate ml/h 13000 13000 13200 18000 20700 35000 34000
Compressor load kW** 9,2 10,0 10,0 14,0 18,4 20,1 23,0
Pump output kW** 0,65 2,2 2,2 2,2 2,2 2,2 2,2
Power load kW 11,1 13,5 13,5 18,3 22,1 27,0 30,0
Voltage V/Hz 3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
3x400/
N/PE/50
Maximum current A 23,2 28,4 28,4 40,0 45,1 56,6 63,4
Dimension: l mm 1670 1670 1910 1910 1910 2460 2460
Dimension: w mm 930 930 1130 1130 1130 1380 1380
Dimension: h mm 1790 1790 1900 1900 2050 2050 2050
Weight kg 540 620 780 850 1100 1300 1600
Refrigerant weight kg 22,5 23,0 34,0 30,0 45,0 46,0 65,0
* The mentioned cooling capacity refers to an ambient temperature of 32°C and a water inlet temperature of 15°C. At lower water inlet temperature the cooling capacity reduces approx. 3% per °C.
** * Nominal capacity according to the manufacturer.

Technical data for standard units, model IK-H (semi-hermetic)

air cooled semi-hermetic AquaCooly IK-H with pipe-coil evaporator
IK-H 2 IK-H 3 IK-H 5 IK-H 7 IK-H 9 IK-H 11 IK-H 15 IK-H 19
Refrigerant R 134 a R 134 a R 134 a R 134 a R 134 a R 134 a R 134 a R 134 a
Nominal power kcal/h* 2100 3700 5900 7600 9500 11200 15000 19000
Nominal power kW* 2,44 4,30 6,85 8,84 11,04 13,03 17,50 22,10
Pump type CM 1-4 CM 1-4 CM 1-4 CM 1-6 CM 1-6 CM 3-6 CM 3-6 CM 3-6
Basin capacity litre 87 87 140 140 140 140 300 300
Pipe connexion R 3/4" R 3/4" R 3/4" R 3/4" R 3/4" R 1" R 1" R 1"
Air flow rate ml/h 2600 2750 4000 5500 8000 8700 13000 13000
Compressor load kW** 1,12 1,89 2,95 3,78 4,49 5,22 5,62 6,97
Pump output kW** 0,45 0,45 0,45 0,45 0,45 0,65 0,65 0,65
Power load kW 1,83 2,54 3,67 4,90 5,87 6,78 7,65 9,01
Voltage V/Hz 400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
Maximum current A 3,9 5,9 7,7 9,5 11,5 16,2 17,7 18,0
Dimension: l mm 730 730 860 860 1470 1470 1670 1670
Dimension: w mm 675 675 760 760 730 730 930 930
Dimension: h mm 1165 1165 1370 1370 1560 1560 1790 1790
Approx. weight kg 160 180 270 280 390 390 610 630
* The mentioned cooling capacity refers to an ambient temperature of 42°C and a water inlet temperature of 15°C. At lower water inlet temperature the cooling capacity reduces approx. 3% per °C.
** * Nominal capacity according to the manufacturer.


air cooled fully-hermetic AquaCooly IK-H with pipe-coil evaporator
IK-H 22 IK-H 28 IK-H 35 IK-H 45 IK-H 55 IK-H 65 IK-H 80 IK-H 95 IK-H 115
Refrigerant R 134 a R 134 a R 134 a R 134 a R 134 a R 134 a R 134 a R 134 a R 134 a
Nominal power kcal/h* 22500 28000 35000 45000 55000 65000 80000 95000 115000
Nominal power kW* 26,20 32,60 40,70 52,30 63,90 75,60 93,00 110,50 133,70
Pump type CM 3-6 CM 10-3 CM 10-3 CM 10-3 CM 10-3 CM 15-2 CM 15-2 CM 15-3 CM 15-3
Basin capacity litre 500 500 500 500 500 500 500 500 500
Pipe connexion R 1" R 1 1/4" R 1 1/4" R 1 1/2" R 1 1/2" R 1 1/2" R 2" R 2" R 2 1/2"
Air flow rate ml/h 13000 13200 13200 20700 31050 35000 45320 46660 68700
Compressor load kW** 9,08 10,14 13,29 20,85 25,11 27,97 34,26 41,50 50,22
Pump output kW** 0,65 2,20 2,20 2,20 2,20 2,20 2,20 4,00 4,00
Power load kW 10,13 13,82 16,23 24,38 29,01 32,71 39,43 49,24 58,59
Voltage V/Hz 400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
400/
50/3/PE
Maximum current A 23,4 27,9 35,4 49,4 59,5 72,7 83,2 99,3 116,9
Dimension: l mm 1670 1800 1910 1800 2460 2460 3000 4400 4400
Dimension: w mm 930 1100 1130 1100 1380 1380 1400 1400 1400
Dimension: h mm 1790 1900 1900 2050 2050 2050 2200 2200 2200
Approx. weight kg 650 750 890 1250 1450 1600 2000 2300 3000
* The mentioned cooling capacity refers to an ambient temperature of 42°C and a water inlet temperature of 15°C. At lower water inlet temperature the cooling capacity reduces approx. 3% per °C. Bei tiefen Wasservorlauftemperaturen verringert sich die Kälteleistung um ca. 3% pro °C.
** Nominal capacity according to the manufacturer.